A typical rooftop solar array in Georgia has a capacity factor of roughly 15–16% on a DC basis, but that number cannot tell a Georgia business what it will save. In our NREL PVWatts run for a 200 kW-dc low-tilt warehouse roof in Macon, the array produced about 272,750 kWh a year (a 15.6% capacity factor), and the same kilowatt-hours were worth anywhere from about $19,300 to $29,600 a year depending on how much of that energy the building used on site.

Capacity factor measures how hard a system works. Savings depend on which bill charges each kilowatt-hour replaces, how much is exported, and how the array ages. This guide shows the difference with Georgia numbers so you can challenge a proposal that leans on capacity factor alone.

What is solar capacity factor, and what is it in Georgia?

Capacity factor is the energy a system actually produces in a year divided by what it would produce running at full nameplate output every hour of the year (8,760 hours). For our illustrative Macon, Georgia example, NREL's PVWatts calculator (version 8.5.0, NSRDB weather data, run November 25, 2026) reports 272,751 kWh a year from 200 kW-dc of fixed panels at 10° tilt facing south with 14% system losses, which PVWatts v8 expresses as a 15.6% capacity factor.

That figure is on a DC basis (divided by the 200 kW of panels). The same system has a 1.2 DC-to-AC ratio, so its inverters are about 166.7 kW-ac. Divide the same energy by the AC rating and the capacity factor becomes 18.7%. Nothing about the roof changed; only the denominator did. Always ask a proposal which basis it uses.

Why do Georgia capacity factors differ between systems?

Orientation and mounting change capacity factor more than most buyers expect: in our PVWatts runs for the same Macon site and the same 200 kW-dc, results ranged from 14.5% to 18.8% on a DC basis. A ground-mounted single-axis tracker produced 21% more energy than the low-tilt rooftop, while an east-west layout produced about 7% less.

Layout (Macon, GA, 200 kW-dc, 14% losses)

Annual output (kWh)

Specific yield (kWh/kW-dc)

Capacity factor, DC basis (%)

Capacity factor, AC basis (%)

Output vs. base case (%)

Roof, fixed, 10° tilt, south (base case)

272,751

1,364

15.6

18.7

0

Fixed, 25° tilt, south

285,633

1,428

16.3

19.6

+4.7

Roof, fixed, 10° tilt, east-west split

253,919

1,270

14.5

17.4

−6.9

Ground mount, single-axis tracker

330,043

1,650

18.8

22.6

+21.0

Source: our NREL PVWatts v8 runs at 32.84° N, 83.63° W (Macon), November 25, 2026; east-west is the average of separate 90° and 270° runs. Illustrative assumptions, not a quote or project data.

This is why utility-scale solar farms, which often use trackers and report on an AC basis, publish higher capacity factors than commercial rooftops. A higher capacity factor can still be the worse investment if the tracker costs more than the extra energy is worth to you.

Why doesn't a higher capacity factor mean higher savings in Georgia?

Because a kilowatt-hour used inside your building and a kilowatt-hour sent to the grid are worth very different amounts. The U.S. Energy Information Administration's 2024 state price data put Georgia's average commercial retail price at 10.87 cents/kWh. Georgia Power's commercial rooftop solar FAQ, checked November 25, 2026, says excess energy under its RNR-Instantaneous Netting program is credited at the annual avoided cost rate, which it lists as 3.3153 cents/kWh for 2025, and notes that a 2022 rate case approved an additional 4 cents/kWh added to the solar avoided cost.

Here is the same 272,751 kWh valued three ways, using 10.87 cents/kWh for energy used on site and 3.3153 cents/kWh for exports:

Share of solar used on site (%)

Annual production (kWh)

Illustrative annual value ($)

Average value per solar kWh (cents)

100

272,751

29,648

10.87

80

272,751

25,527

9.36

50

272,751

19,345

7.09

Our calculation. Illustrative assumptions, not a quote, a tariff statement or project data. Adding the 4-cent adder Georgia Power describes would raise the export value; confirm how it applies to your account.

Capacity factor is identical in all three rows. The value per kilowatt-hour falls by about a third as exports rise. Two more cautions keep this example honest:

  • The average price is not your offset price. EIA's 10.87 cents is total revenue divided by total sales, so it includes demand charges and fixed fees. Solar reliably cuts energy charges, but it may barely touch a monthly demand peak set at 6 p.m. on a cloudy August day. Your real energy-only offset may be lower.

  • Program limits apply. The same Georgia Power page caps eligibility at 250 kW-ac, limits systems between 100 and 250 kW-ac to 125% of the prior year's metered peak demand, and enrolls first come, first served up to a program cap.

Many Georgia businesses are served by an EMC (electric membership corporation) or a city utility rather than Georgia Power. Their buy-back, netting and interconnection rules differ, so check your own utility's current tariff before you value any exported kilowatt-hour.

How much does Georgia solar output change by season?

A lot: in our Macon PVWatts run, December produced 15,808 kWh and May produced 29,383 kWh, so December was only about 54% of May. An annual capacity factor hides this swing, yet it matters for monthly bills, demand charges and any netting that resets each month.

If your building's load peaks in winter (for example, electric heating or a process that runs harder in the cold), solar will cover less of it than the annual average suggests. Summer-peaking loads such as cooling, refrigeration and cold storage line up better with Georgia's solar months.

How does degradation change the numbers over 25 years?

Output falls slowly every year, so year-one capacity factor overstates lifetime production. NREL's PV Fleet Performance Data Initiative, which analyzes almost 2,500 commercial and utility sites, reported a national median performance loss of 0.75% per year.

Applying 0.75% a year to our Macon base case, output falls from 272,751 kWh in year 1 to about 254,883 kWh in year 10 and about 227,666 kWh in year 25, a drop of roughly 17%. A savings model that multiplies year-one output by 25 overstates lifetime energy. Ask what degradation rate a proposal assumes and whether it matches the module warranty.

What should a Georgia business ask instead of "what's the capacity factor?"

Ask for an hourly or at least monthly production estimate matched against your own interval meter data. That one request turns capacity factor into something you can value. Then ask:

  1. Is the capacity factor on a DC or AC basis, and what tilt, azimuth, losses and weather data were used?

  2. What share of production will be used on site each month, and how was that estimated from my load data?

  3. What rate is each kilowatt-hour valued at: energy charge, demand charge or export credit, under my utility's current tariff?

  4. What degradation rate, inverter replacement and O&M costs are included?

  5. Which federal tax credit assumptions are used, and has a tax professional confirmed eligibility? IRS Notice 2025-42 explains that the Section 45Y and 48E credits terminate for wind and solar facilities that begin construction after July 4, 2026 and are placed in service after December 31, 2027.

Assumptions and limits

All production figures are single PVWatts v8 runs for one Macon, Georgia location using typical-year NSRDB weather, 14% losses, standard modules and a 1.2 DC-to-AC ratio. Real systems vary with shading, soiling, roof condition, equipment and weather in any given year. The savings table uses a statewide average commercial price and a published avoided-cost rate purely to show how value changes with self-consumption; it is not a tariff calculation for any account. This is general information, not financial, legal, tax, structural or electrical advice. Any project needs utility approval, local permits and a licensed contractor, and incentives should be confirmed with a tax professional.

Frequently asked questions

What is a good solar capacity factor in Georgia?

For fixed rooftop arrays, our PVWatts runs for Macon gave about 14.5–16.3% on a DC basis depending on tilt and orientation, and about 18.8% for a ground-mounted tracker. "Good" depends on cost: a lower capacity factor at a much lower price per watt can still win.

How do I convert capacity factor to annual kWh?

Multiply the system size by 8,760 hours and by the capacity factor, using the same basis. For example, 200 kW-dc × 8,760 × 15.6% ≈ 273,000 kWh, which matches our PVWatts result.

Is capacity factor the same as panel efficiency?

No. Panel efficiency is the share of sunlight a module converts to electricity under test conditions. Capacity factor describes how much energy a whole system produces over a year relative to its rating, so it reflects weather, sun angle, orientation and losses too.

Why does my utility bill not fall in line with solar production?

Bills include demand charges, fixed charges and export credits that do not scale with kilowatt-hours produced. Exported energy credited near avoided cost is worth far less than energy used on site, so the share you self-consume often matters more than total output.

More Georgia solar analysis

If you are weighing a commercial project, these ReneEnergy posts go deeper on the pieces that capacity factor leaves out:

Browse every post in our Going Solar category.

Sources

  1. NREL / National Laboratory of the Rockies, PVWatts v8 API (runs for Macon, GA, November 25, 2026).

  2. U.S. Energy Information Administration, Average retail price of electricity by state and sector, 2024 (Table 4).

  3. Georgia Power, Commercial rooftop installations FAQs (checked November 25, 2026).

  4. NREL, How extreme weather and system aging affect the U.S. photovoltaic fleet (2024).

  5. Internal Revenue Service, Notice 2025-42.

Fact-checked November 25, 2026.