top of page

Water Electrolysis: How Hydrogen Is Made From Water

4 minutes ago
6 min read

Last updated November 23, 2026 · By Alex, ReneEnergy

Water electrolysis makes hydrogen by passing electricity through water, splitting each water molecule into hydrogen gas at one electrode and oxygen gas at the other. A modern PEM electrolyzer system used about 55 kWh of electricity per kilogram of hydrogen in 2022, according to the US Department of Energy (DOE), and every kilogram needs at least about 9 kg of purified water.

That is the whole idea in two sentences. The rest of this guide explains what happens inside the machine, how the three main electrolyzer types differ, what "green" really means, and where electrolysis is not the best answer.

How does water electrolysis make hydrogen?

Water electrolysis uses a direct electric current to break water (H2O) into hydrogen (H2) and oxygen (O2) inside a device called an electrolyzer. The DOE's electrolysis explainer (updated October 13, 2026) describes every electrolyzer as an anode and a cathode separated by an electrolyte, much like a fuel cell running in reverse.

Picture it as a simple sandwich:

  1. Negative electrode (cathode): hydrogen gas bubbles off here.

  2. Electrolyte in the middle: a membrane, a liquid or a ceramic that lets only one kind of charged particle (ion) through.

  3. Positive electrode (anode): oxygen gas bubbles off here.

Power goes in, the ions cross the electrolyte, and the two gases leave through separate outlets. A real electrolyzer "stack" repeats this sandwich hundreds of times, then adds pumps, water purification, power electronics, gas drying and cooling around it.

What are the three main types of electrolyzer?

The three main types are PEM, alkaline and solid oxide (SOEC), and they differ mainly in their electrolyte and the ion it carries. The operating temperatures below come from the DOE electrolysis page (2026).

Type

Electrolyte

Ion that moves

Operating temperature (°C)

In plain words

PEM (proton exchange membrane)

Solid plastic membrane

H+ (protons)

70–90

Compact, starts quickly, popular with wind and solar

Alkaline

Liquid potassium or sodium hydroxide with a porous separator

OH− (hydroxide)

60–90

The oldest, most established design

AEM (anion exchange membrane)

Solid polymer membrane

OH− (hydroxide)

50–80

A newer hybrid of the two ideas above

SOEC (solid oxide)

Solid ceramic

O2− (oxide)

650–850

Runs very hot; can use waste heat to cut electricity use

The DOE notes that SOECs can use heat from sources such as nuclear plants, which reduces the electricity needed to split water. That is the trade: PEM and alkaline units use only electricity, while SOEC swaps part of the electricity for high-temperature heat.

Choosing between them for a real plant is a different question, with cost, stack life and flexibility in play. H2Hub covers that in PEM vs Alkaline Electrolyzer: How to Choose for a Hydrogen Project.

How much electricity does it take to make 1 kg of hydrogen?

A PEM electrolyzer system used about 55 kWh per kilogram of hydrogen in 2022, and the DOE's target is 51 kWh/kg in 2026 and 46 kWh/kg in the long run, according to its PEM electrolysis technical targets (page updated May 29, 2026). The DOE rates that 55 kWh/kg status at 61% efficiency on a lower heating value basis.

Put another way: the DOE's own figures imply that a kilogram of hydrogen holds roughly 33 kWh of usable chemical energy (55 × 61% ≈ 33.6 kWh), so about two-fifths of the electricity is lost as heat in today's systems. That loss is the main reason hydrogen made by electrolysis costs more than the electricity that went into it.

How much water does electrolysis use?

Chemistry sets the floor at about 8.9 kg of water for every kilogram of hydrogen, because a water molecule (18.0 g/mol) holds only 2.0 g/mol of hydrogen. Real plants draw more than that, since water must be purified first and cooling systems may use extra water.

The same split also releases about 7.9 kg of oxygen per kilogram of hydrogen, which some plants vent and others sell. For how intake, treatment and cooling add up at a 100 MW project, see H2Hub's worked water-requirements example.

What does a 1 MW electrolyzer produce in a day?

A 1 MW electrolyzer running flat out for 24 hours produces roughly 440 kg of hydrogen at today's 55 kWh/kg, using about 3.9 tonnes of water as the chemical minimum. This is our own illustrative calculation (24,000 kWh ÷ kWh per kg), built on the DOE efficiency figures above.

Efficiency case (DOE)

Electricity use (kWh/kg H2)

Hydrogen per day from 1 MW (kg)

Minimum water per day (tonnes)

2022 status

55

436

3.9

2026 target

51

471

4.2

Ultimate target

46

522

4.7

Illustrative only: assumes full power for all 24 hours and the chemical minimum of 8.94 kg water per kg H2. Real plants rarely run at full output every hour, and usually draw more water.

The table shows why efficiency matters: the same megawatt makes about 20% more hydrogen at the ultimate target than at 2022 performance. The gap between a plant's megawatts and its yearly output is explained in our post on electrolyzer MW vs annual hydrogen output.

Is hydrogen from electrolysis always green?

No: electrolysis hydrogen is only as clean as the electricity behind it. It is usually called "green" when the power comes from renewables such as wind or solar; run on fossil-heavy grid power, it can carry a large carbon footprint.

Today almost all hydrogen is still made from fossil fuels. The IEA Global Hydrogen Review 2026 reports that global hydrogen demand passed 100 million tonnes in 2025, while low-emissions production reached only almost 1 Mt, and installed electrolysis capacity doubled in 2025 to exceed 4 GW. Most hydrogen still comes from unabated fossil fuels, for example natural gas through steam methane reforming ("grey" hydrogen, or "blue" when the CO2 is captured).

When is electrolysis not the best option?

Electrolysis is a poor fit wherever the electricity could do the job directly, because roughly 40% of the energy is lost before the hydrogen is even used (DOE 2022 status, above). Using hydrogen in a fuel cell or engine loses more again.

  • Cars, home heating and short-range vans: batteries and heat pumps usually use the same electricity far more efficiently.

  • Fossil-heavy grids: at about 55 kWh per kilogram, an electrolyzer on coal- or gas-heavy power inherits a large carbon footprint, so the hydrogen is not low-emissions.

  • Dry regions with no plan for water: the water need is modest per kilogram but real, and it has to be secured and treated.

Where it does make sense: replacing grey hydrogen that industry already uses, such as in fertilizer and refining. Our guide to what hydrogen is used for covers those uses and their limits.

Frequently asked questions

Can you make hydrogen from tap water?

Not directly in an industrial electrolyzer. Tap water carries minerals that foul membranes and electrodes, so electrolyzers use purified (deionized) water. Small classroom demonstrations work with salty or tap water, but they are not built to run for years.

What is the difference between electrolysis and steam methane reforming?

Electrolysis splits water with electricity, while steam methane reforming reacts natural gas with steam and releases CO2. Fossil routes like reforming still make most of the world's hydrogen (IEA, 2026); electrolysis is the main route to low-emissions hydrogen when the power is clean.

Which electrolyzer type is the most efficient?

SOEC can need the least electricity per kilogram because it uses high-temperature heat for part of the energy, according to the DOE. PEM and alkaline units run near 50–90 °C on electricity alone. The best choice for a project also depends on cost, stack life and how often the power supply changes.

Is electrolysis the same as HHO gas?

Both split water with electricity, but HHO devices mix the hydrogen and oxygen into one gas stream. Industrial electrolyzers keep the two gases apart with a membrane or separator, which is safer and gives usable, pure hydrogen.

Screening a real hydrogen project?

If you are moving from "how does it work" to "would a plant work here", H2Hub lets you start a project without an account or a card, and your first full project report is free. Start a free project screen in H2Hub.

Related reading

Sources

  1. US Department of Energy, Hydrogen Production: Electrolysis, last updated October 13, 2026.

  2. US Department of Energy, Technical Targets for Proton Exchange Membrane Electrolysis, last updated May 29, 2026.

  3. International Energy Agency, Global Hydrogen Review 2026, Executive summary, 2026.

  4. ReneEnergy calculation: molar masses of water (18.015 g/mol), hydrogen (2.016 g/mol) and oxygen (15.999 g/mol); daily output = 24,000 kWh ÷ kWh/kg.

Fact-checked November 23, 2026.

Recent Posts

See All

Comments


Technical films · About · H2Hub · Hydrogen industry directory · Blog · Shop · Feasibility template · Privacy policy · Affiliate disclosure · Contact

As an Amazon Associate, ReneEnergy earns from qualifying purchases.

bottom of page